DynamixUMSNBUserManualVer1.00105
Setup Serial Parameter, RTS
The behavior of the RTS (Request To Send) signal may be set in one of two ways. When set 'on', the RTS signal is always
forced on (active low), when set 'from DTE' the RTS signal will follow the DTE's condition. The default setting for RTS is on.
Setup Serial Parameter, CTS
The behavior of the CTS (Clear To Send) signal may be set in one of three ways. When set 'on', the CTS signal is always
forced on (active low), when set 'off' the signal is always forced off, or CTS will follow RTS (Request To Send) condition of 'on'
for RTS on 'off' for RTS off. The default setting for CTS is to follow RTS.