01.99 6 Programming
6FC5198-6AA60-0BP1 © Siemens AG 1999 All Rights Reserved
6-16 SINUMERIK 840C, OEM Version for Windows (BA)
6.2.3.3 Syntax description for the job lists
Four types of instruction are used in the job lists:
Comments
Clear instruction CLEAR
Load instruction LOAD or LOADCYC
Select instruction SELECT.
This sequence is mandatory.
All terms in round brackets are comments and are not taken into account when
processing the job list. Comments must stand on their own in a line.
With the CLEAR instruction, part programs are deleted from the NCK part
program memory.
CLEAR
name
[attr.]L
F
( = ’blank’)
The following identifiers can be used for "name":
MPFn (one main program)
SPFn (one subroutine)
MPF[n,m] (part programs MPFn...MPFm)
SPF[n,m] (subroutines SPFn...SPFm)
MPF* (all main programs)
SPF* (all subroutines)
* refers to all part programs in the part program memory (in the NCK).
The following attribute can be used for the CLEAR command:
-u (unconditional deletion)
If cycle disable is not set, cycles can be deleted in the NCK memory
independently of their status.
Deletion of the MPF7 part program:
CLEAR
MPF7 L
F
Deletion of all subroutines or cycles SPF 1 to 999:
CLEAR
SPF[1, 999]
-u L
F
Deletion of all MPF, SPF:
CLEAR
* L
F
Caution! The syntax is mandatory. Observe the position of the blanks
.
Comment
CLEAR instruction
Command syntax
Examples